Bellini CGH9501 Provozní pokyny Strana 6

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 13
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 5
Bellini – 60/90cm gas hob
Rev: 8-9-2010 4
4. TROUBLESHOOTING
Servicing of the hotplates must only be done by an authorised service representative (see
back of this booklet) and the hotplate must not be modified. Power must be disconnected
before any servicing or maintenance is conducted.
Abnormal conditions include : Excessively yellow or sooting flame type.
: Flame lifting off the burner ports.
: Flame lighting back into the burner (normally associated with a
popping sound).
: Objectionable odour of the flames combustion products.
Should a faulty condition develop in the hotplate that is not described above, refer to the
following table first for possible causes and remedies prior to contacting an authorised service
representative. Servicing beyond the remedies listed shall only be undertaken by an
authorised service representative.
TROUBLESHOOTING TABLE
FAULT POSSIBLE CAUSE REMEDY
No spark when gas control knob
depressed. No power.
Check plugged in and switched
on. Check mains circuit breaker.
Loose sparker cable. Call authorised representative.
Burner not aligned properly. Remove and re-fit burner.
Burner not lighting when spark
ignition working. Gas supply off. Check gas supply valve on.
Burner not aligned properly. Remove and re-fit burner.
Burner ports blocked.
Remove, clean and replace
burner.
Burner goes out when control
knob released.
Flame safeguard not
activated.
Re-light, allow more time for
flame safeguard to activate.
Flame safeguard faulty
connection or broken. Call authorised representative.
Uneven flame pattern or slight
flame lifting. Burner ports blocked.
Remove, clean and replace
burner.
At minimum flame setting the
flame is too high.
Turndown control setting
incorrect. Call authorised representative.
Small flame on High setting. Regulator faulty. Call authorised representative.
Gas supply pressure low. Call authorised representative.
Incorrect injector fitted. Call authorised representative.
Blocked injector or gas supply
tube. Call authorised representative.
Incorrect utensil size.
Refer to operating instructions -
utensil choice.
Flame too high on High setting. Regulator faulty. Call authorised representative.
Incorrect injector fitted. Call authorised representative.
Incorrect utensil size.
Refer to operating instructions -
utensil choice.
4
Zobrazit stránku 5
1 2 3 4 5 6 7 8 9 10 11 12 13

Komentáře k této Příručce

Žádné komentáře